The charts and drawings show recommended sizes and capacities for typical building installations. These dimensions should be used as a preliminary planning guide. Please contact Schumacher Elevator or your Schumacher distributor for additional information before beginning construction.

Pit & Overhead Dimensions
Speed (FPM) 75 100 125 150 200
Overhead (O) 12'0" 12'0" 12'4" 13'0" 13'6"
Pit (P) 4'0" 4'0" 4'0" 4'0" 4'6"

Single-End Opening
Hoistway Platform Inside Car Door
Cap. Width (A) Depth (B) Width (C) Depth (D) Width (E) Depth (F) Width (G) Type
2000
7'8" 6'0" 6'0" 5'1.5" 5'8" 4'3" 3'0" Single Slide
2500
8'8" 6'0" 7'0" 5'1.5" 6'8" 4'3" 3'6" Single Slide or Center Parting
3000
8'8" 6'6" 7'0" 5'7.5" 6'8" 4'9" 3'6" Single Slide or Center Parting
3500
8'8" 7'0" 7'0" 6'1.5" 6'8" 5'3" 3'6" Single Slide or Center Parting

These elevators meet the minimum size required by ADA.

Two-End Opening
Hoistway Platform Inside Car Door
Cap. Width (A) Depth (B) Width (C) Depth (D) Width (E) Depth (F) Width (G) Type
2000
7'8" 6'8.5" 6'0" 5'8" 5'8" 4'3" 3'0" Single Slide
2500
8'8" 6'8.5" 7'0" 5'8" 6'8" 4'3" 3'6" Single Slide or Center Parting
3000
8'8" 7'2.5" 7'0" 6'2" 6'8" 4'9" 3'6" Single Slide or Center Parting
3500
8'8" 7'8.5" 7'0" 6'8" 6'8" 5'3" 3'6" Single Slide or Center Parting

These elevators meet the minimum size required by ADA.
 

 

 
   
 