The charts
and drawings
show
recommended
sizes and
capacities
for typical
building
installations.
These
dimensions
should be
used as a
preliminary
planning
guide.
Please
contact
Schumacher
Elevator or
your
Schumacher
distributor
for
additional
information
before
beginning
construction.
Pit &
Overhead
Dimensions
Speed
(FPM)
75
100
125
150
200
Overhead
(O)
12'0"
12'0"
12'4"
13'0"
13'6"
Pit (P)
4'0"
4'0"
4'0"
4'0"
4'6"
Single-End
Opening
Hoistway
Platform
Inside
Car
Door
Cap.
Width
(A)
Depth
(B)
Width
(C)
Depth
(D)
Width
(E)
Depth
(F)
Width
(G)
Type
2000
7'8"
6'0"
6'0"
5'1.5"
5'8"
4'3"
3'0"
Single
Slide
2500
8'8"
6'0"
7'0"
5'1.5"
6'8"
4'3"
3'6"
Single
Slide or
Center
Parting
3000
8'8"
6'6"
7'0"
5'7.5"
6'8"
4'9"
3'6"
Single
Slide or
Center
Parting
3500
8'8"
7'0"
7'0"
6'1.5"
6'8"
5'3"
3'6"
Single
Slide or
Center
Parting
These elevators
meet the minimum
size required by
ADA.
Two-End
Opening
Hoistway
Platform
Inside
Car
Door
Cap.
Width
(A)
Depth
(B)
Width
(C)
Depth
(D)
Width
(E)
Depth
(F)
Width
(G)
Type
2000
7'8"
6'8.5"
6'0"
5'8"
5'8"
4'3"
3'0"
Single
Slide
2500
8'8"
6'8.5"
7'0"
5'8"
6'8"
4'3"
3'6"
Single
Slide or
Center
Parting
3000
8'8"
7'2.5"
7'0"
6'2"
6'8"
4'9"
3'6"
Single
Slide or
Center
Parting
3500
8'8"
7'8.5"
7'0"
6'8"
6'8"
5'3"
3'6"
Single
Slide or
Center
Parting
These elevators
meet the minimum
size required by
ADA.